Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing

Product Details
Customization: Available
After-sales Service: One-Year Warranty
Application: Industrial
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
18
Year of Establishment
2014-03-26
  • Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
  • Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
  • Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
  • Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
  • Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
CYY-9000
Warranty
1 Year
Detection Method
Spectrograph
Advantage
High Sensitive
Principle
Classic Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Polychromator
Customized
Customized
Application Field
Foundry Steel, Metallurgy, Metal Analysis
Instrument Weight
About 90kg
Optical System
PAR-Rungeroland Circular Full Spectrum Vacuum Opti
Transport Package
Professional Wooden Case for Export
Specification
L850*W700*H500mm
Trademark
CYY
Origin
Made-in-China
HS Code
9027300000
Production Capacity
500set/Year

Product Description

 

Product Description

Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing

         CYY-9000 full spectrum direct reading spectrometer adopts the international standard design and manufacturing technology, adopts the full digital technology, replaces the huge PMT simulation technology, synchronizes with the international spectrometer technology, adopts the vacuum optical chamber design and full digital excitation light source, leading CCD detector, high-speed data readout system, so that the instrument has extremely high performance and low cost Detection line, long-term stability and repeatability. It is used in iron and steel casting, metal manufacturing, mechanical processing, metal smelting, shipbuilding, automobile and aerospace, material quality control, material brand identification, material research, development and production.

 

 

Detailed Photos

 
Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
 
Detection Matrices:
Iron(Fe) and its alloys (Steel alloy, Cast iron, Fe-Low alloy, Fe-Cr steel, Fe-Cast iron, Fe-Cr-cast, Fe-Mn steel, Fe-Tool steel etc.)
Aluminium(Al) and its alloys (Al-Si alloy, Al-Zn alloy, Al-Cu alloy, Al-Mg alloy, Pure-Al alloy etc)
Copper(Cu) and its alloys (Brass, Copper-Nickel-Zn, Aluminum Bronze, Tin-lead Bronze, Red Copper, Be-Bronze, Si-Bronze etc)
Nickel(Ni) and its alloys (Pure Ni, Monel metal, Hadtelloy Alloy, Incoloy, Inconel, Nimonic etc)
Cobalt(Co) and its alloys (Co-orientation, Low Co alloy, Stellite 6,25,31, Stellite 8,WI 52, Stellite 188, F)
Magnesium(Mg) and its alloys (Pure Mg, Mg/Al/Mn/Zn-alloys)
Titanium(Ti) and its alloys
Zinc(Zn) and its alloys
Lead(Pb) and its alloys
Tin(Sn) and its alloys
Argentum(Ag) and its alloys
Small sample, special size sample and wire detection
Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing

 

Product Parameters

 

Project Index   
Testing matrix Fe, Al, Cu, Ni, Zn, Mg, etc
Iron base, aluminum base, copper base, nickel base, zinc base, magnesium base, etc
Test time It depends on the type of sample, generally about 25s
Optical system A full spectrum vacuum optical system based on Paar rungellan circle
Wavelength range 130~800nm
Focal length (circle radius) 400mm
Detector (sensor) High performance CCD array
Electrode Tungsten spray electrode
Analysis gap Analysis gap of sample table: 3.4mm
Working temperature (10~35)ºC
Storage temperature (0~45)ºC
Working humidity 20%~80%
Purity and quality requirements of argon 999%, air pressure ≥ 4MPa
Argon inlet pressure 0.5MPa
Argon flow rate The excitation flow rate is about 3.5l/min and the maintenance flow rate is about 0.4l/min
Excitation maximum power 400W
Type of light source New adjustable digital light source, high energy pre ignition technology (HepS)
Discharge frequency 100-1000 Hz
Aperture of exciter 13mm
Vacuum system Automatic control and monitoring of vacuum software
Working power supply 220V AC, 50/60 Hz, single phase power supply with protective grounding
Instrument size 850*700*500mm
Instrument weight More than 90kg (table type, without vacuum system);More than 120kg (vertical)
 

Packaging & Shipping

About  spectrometer order procedure
1.Please company or factory and related personnel Determine the material of the product to be tested and the relevant instruments required.
2.We'll quantity through e-mail or WeChatNegotiate all details about this order. 
3.Negotiated payment as advanced payment reached, Tell consignee information, Calibrate the target material into the instrument again, and prepare the standard sample and accessories according to the material and requirements selected by the customer .
4.Ship out goods as the balance payment received,Send out documents that customers required.
5.Customers signed the good, and engineer fly there to installation Train 1-2 operators.
6.Warranty 1 year after installation,Daily use details or questions can also be answered by network remote transmission.
7.After-sale department call back to survey the customers' satisfication ,Communicate on a regular basis.

 

Installation Instructions

 
Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
About training
After the instrument arrives at the port, please load and unload it in time and transport it to the laboratory prepared by the factory (or unit) in advance. Then check whether the outer package is damaged or not, as well as the condition of the internal instrument products. After checking the list, our company will assign the installation engineer to go on a business trip to the local area to carry out on-site installation and commissioning, and train 1-2 personnel suitable for operation. The training time is usually completed within 3-4 days of arrival. Through training, the relevant personnel master the use of spectral analysis, skilled instrument operation and maintenance. Later in the process of use, if you have technical questions, you can also communicate in time through remote network chat tools, and communication is convenient. The overall analysis process of the instrument is automatic, learning to use is relatively simple, as long as the operator is careful, will normally use the computer, there is a certain degree of education can be mastered.

 

Company Profile

Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing
Cyy-9000 Full Spectrum Direct Reading Spectrometer for Steel Casting, Metal Manufacturing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier